Current:Home > E F G H
E F G H
EATON
2017-03-30 12:29:10
 
 
 
 
DIL EM-01-G(12VDC)
DIL EM-01-G(24VDC)
DIL EM-01-G(48VDC)
DIL EM-01-G(110VDC)
DIL EM-01-G(220VDC)
DIL EM-01-G-C(24VDC)
 
DILEM-01-G(12VDC)
DILEM-01-G(24VDC)
DILEM-01-G(48VDC)
DILEM-01-G(110VDC)
DILEM-01-G(220VDC)
DILEM-01-G-C(24VDC)
 
 
MOELLER DILEM-01-G
is now
 EATON XTMC9A01
SAME EXACT PART -  ONLY PART # CHANGE - CLICK THE XTCE NUMBER TO VIEW THE NEW PAGE
 
Part #
 
Hp @ 230 HP @ 460 Amps Normally Open Pwr Normally Open Aux Normally Closed Aux
DILEM-01-G 3 5 9 3 0 1
`
DILEM-01-G Ordering Information
Part Name Article 
Number Rated 
Operational 
Current
le
A
AC-3 Max. rating for three 
phase motors, 50 60 Hz
UL /  CSA Hp Aux Contacts
230 V 460 V NO NC
DILEM-01-G
(110VDC) 10136 9A 3 5 0 1
DILEM-01-G
(12VDC) 7942 9A 3 5 0 1
DILEM-01-G
(220VDC) 10168 9A 3 5 0 1
DILEM-01-G
(24VDC) 10343 9A 3 5 0 1
DILEM-01-G
(48VDC) 10496 9A 3 5 0 1
DILEM-01-G
(60VDC) 10040 9A 3 5 0 1
DILEM-01-G-C
(110VDC) 231694 9A 3 5 0 1
DILEM-01-G-C
(12VDC) 231691 9A 3 5 0 1
DILEM-01-G-C
(220VDC) 231695 9A 3 5 0 1
DILEM-01-G-C
(24VDC) 230167 9A 3 5 0 1
DILEM-01-G-C
(48VDC) 231692 9A 3 5 0 1
DILEM-01-G-C
(60VDC) 231693 9A 3 5 0 1
Klockner Moeller Electric DILEM-01-G
 
 
Includes:
 
Qty 1 - DILEM-01-G 
(AC Operated Contactor) as indicated by the red arrow and green coloring. Overload Relays and Suppressors sold separately.
 
Miniature contactors with positively driven contacts. Not in the case of early-make or late-break contacts. The DC operated contactors are supplied as standard with a diode/resistor combination
surge suppressor. Coil power consumption: 2,6 W Contactor contacts to EN 50 012 Auxiliary contact module contact: ...DIL EM to EN 50 012 ...DIL E to EN 50 005 Contacts to EN 50 012 should be given preference.
 
 
 
 
Miniature Contactors
Miniature contactors with positively driven contacts, except in the case of early-make or late-break contacts. The DC operated contactors (-G) are supplied as standard with a diode/resistor combination surge suppressor. Coil power consumption: 2,6 W Contactor contacts to EN 50 012 Auxiliary contact module contact: ...DIL EM to EN 50 012 ...DIL E to EN 50 005 Contacts to EN 50 012 should be given preference.
 
Basic Models
Klockner Moeller Electric DILEM
Contactor indicated by green color and red arrow.
 
Part# Hp @ 230 HP @ 460 Amps Normally Open Power Normally Open Aux Normally Closed Aux
DILEM-10 3 5 15 3 1 0
DILEM-10-G 3 5 15 3 1 0
DILEM-01 3 5 15 3 0 1
DILEM-01-G 3 5 15 3 0 1
DILEM-4 3 5 15 4 0 0
 
 
 
 
 
DILEM
Auxiliary Contacts
 Klockner Moeller Electric DILEM
 
FOR USE ON "DILEM" Amps Normally Open Normally Closed
 
02DILEM FOR USE ON "DILEM" 10 0 2
11DILEM 10 1 1
22DILEM 10 2 2
 
DILER
Auxiliary Contacts
Klockner Moeller Electric DILER
 
FOR USE ON "DILER" Amps Normally
Open Normally Closed
 
02DILE FOR USE ON "DILER" 10 0 2
11DILE 10 1 1
20DILE 10 2 0
11DDILE 10 1 1
04DILE 10 0 4
13DILE 10 1 3
22DILE 10 2 2
31DILE 10 3 1
40DILE 10 4 0
22DDILE 10 2 2
DILEM-4-G 3 5 15 4 0 0
 
 
 
DILM Accessories
 
PART # CONTACTOR FOR USE ON DESCRIPTION FUNCTION
RCBDIL48 DIL00AM, DIL00M, DIL0AM, DIL0M, DIL1AM, DIL1M, DIL2AM, DIL2M RC Suppressors For AC operated contactors, 50 – 60 Hz.
Drop-out delay should be taken into
consideration.
RCBDIL250
RCBDIL415
RCSDIL48 DIL3M80, DIL4M115 RC Suppressors For AC operated contactors, 50 - 60 Hz. Drop out delay should be taken into consideration.
RCSDIL250
RCSDIL415
VGBDIL24 DIL00AM, DIL00M, DIL1AM, DIL1M, DIL2AM, DIL2M, DIL3M80, DIL4M115 Varistor Suppressors For AC operated contactors, 50 – 60 Hz,
(DIL00M to DIL4M115) and DC operated
contactors (DIL00M-G to DIL2AM-G).
DC operated contactors DIL3M80 to
DIL4M115 have an integrated varistor
suppressor as standard.
VGBDIL48
VGBDIL250
VGBDIL415
VGCDIL24 DIL00AM, DIL00M, DIL0AM, DIL0M, DIL1AM, DIL1M, DIL2AM, DIL2M Suppressors For DC operated and AC operated contactors
DIL00M to DIL2AM
VGCDIL48
VGCDIL250
VGCDIL415
FDBDIL DIL00M, DIL00AM, DIL0M, DIL0AM, DIL1AM, DIL1M, DIL2AM, DIL2M Free-wheel diode suppressor For DC operated contactors. Drop-out delay should be taken into consideration.
S1DIL00M DIL00M & DIL00AM STAR BRIDGE
SOLID JUMPER THAT CONNECTS ALL 3 POWER POLES TOGETHER. HAS NO INCOMING WIRE TERMINAL CONNECTIONS.
S1DIL0M DIL0M & DIL0AM
S1DIL1M DIL1M & DIL1AM
S1DIL2M DIL2M & DIL2AM
S1DIL3M DIL3M80
S1DIL4M DIL4M115
DILM400-XS1 DILM185-DILM400
DILM500-XS1 DILM500
P1DIL00M DIL00M & DIL00AM PARALLELING BRIDGE
SOLID JUMPER THAT CONNECTS ALL 3 POWER POLES TOGETHER AND HAS A SINGLE INCOMING TERMINAL CONNECTION.
P1DIL0M DIL0M & DIL0AM
P1DIL1M DIL1M & DIL1AM
P1DIL2M DIL2M & DIL2AM
P1DIL3M DIL3M80
P1DIL4M DIL4M115
DILM185-XP1 DILM185
MVS-WB-00M DIL00(A)M REVERSING JUMPER KIT
(1) MVDILM-Mechanical Interlock.
 
 Must be purchased separately
 
Consisting of one 3 pole paralleling link (top) and reversing link with A2 coil bridge (bottom). To form a reversing contactor. An overload module cannot be directly connected to the contactor and if needed must be mounted remotely.
MVS-WB5MV DIL00(A)M+MVDILM (1)
MVS-WB-0M DIL0(A)M
MVS-WB-11MV DIL0(A)M+MVDILM (1)
DIUL0(A)M/MV
MVS-WB-1M DIL1(A)M
DIUL1(A)M
BT480 All top mounting auxiliary contacts Paralleling Links Not insulated. Standard Quantity: 100
AKDIL3M DIL3M80 Adapter Set
consisting of six adapters for cable lug connection For connecting cables with crimped lugs. Set includes 2 terminal covers.
AKDIL4M DIL4M115
MVDILM DIL00(A)M, DIL0(A)M, DIL1(A)M, DIL2(A)M MECHANICAL INTERLOCK KIT For providing mechanical interlock between 2 contactors. No side mount auxiliary contacts may be used except on the opposite sides of the MV module.
DILM500-XMV DIL3M80, DIL4M115, DILM185, DILM225,DILM250, DILM300, DILM400,DILM500
DILM820-XMV DILM580, DILM650, DILM758, DILM820
DILM225-XKU-S DILM185, DILM225 Cable Terminal Block with control circuit terminal For cable connection. Single or double cables may be
connected.
DILM400-XKU-S DILM250, DILM300, DILM400
DILM650-XKB-S DILM500, DILM580, DILM650 Flat Strip Conductor Terminal Kit For bus and flexibus connection.
DILM820-XKB-S DILM750, DILM820
ZKDIL0M DIL0AM, DIL0M Control Circuit Terminals Pressure wire connectors mounted directly to the main
terminals for control circuit tap-off.
15A, 600V max., AWG 18 - 14
ZKDIL1M DIL1AM, DIL1M
DIL2AM, DIL2M
ZKDILM DIL3M80, DIL4M115
HKDILM DIL1AM, DIL1M
DIL2AM, DIL2M Main Terminal For connecting large cross-sections,
For connection of:
up to 50 mm2 stranded
or 35 mm2 flexible with ferrule
DILM400-XHB DILM185, DILM22, DILM250, DILM300, DILM400 Terminal Cover Protection against shock hazards and accidental contact
DILM500-XHB DILM500
DILM650-XHB DILM580, DILM650
DILM820-XHB DILM750, DILM820
V0DIL DIL00M, DIL00AM, DIL0AM, DIL0M, DIL1AM, DIL1M, DIL2AM, DIL2M Coupling
Connector 0 mm distance between contactors
V5/15DIL 5mm between contactors, for contactors with DC coil 15mm between contactors, for mechanical interlock between contactors.
V10/A5DIL 10mm between contactors, for mounting one side mounting auxiliary contact between two contactors 5mm between contactors for contactors with DC coil without permanent connection.
CS-TE ETS4-VS3 For screw mounting of ETS4-VS3
TPE11DIL DIL00M-DIL2AM Top Mount ON Delay Timer Snaps on the top of the contactor and provided (1) Normally Open and (1) Normally Closed Timed Contact. Adjustment ranges either (0.2-30) or (20-180) seconds.
TPD11DIL DIL00M-DIL2AM Top Mount OFF Delay Timer
V-GDIL
(24vdc) DIL00M Top Mount Latching Module With addition of this module a standard DIL00M becomes a Latching relay. Pulse the DIL00M coil to Latch and pulse the module coil to UNLATCH.
V-DIL
(120VAC) DIL00M
NDIL0M DIL0M 4th Power Pole. Adding this module to a standard 3 pole contactor makes it a 4 Pole Power contactor Continuous Rating Open 35 Amps.
Continuous Rating Closed 30 Amps.
 
NDIL1M DIL1M Continuous Rating Open 55 Amps.
Continuous Rating Closed 44 Amps.
 
NDIL2M DIL2M Continuous Rating Open 75 Amps.
Continuous Rating Closed 60 Amps.
 
BT483 DILEM
DIL00M to DILM820 Connection tabs for fast-on connectors For auxiliary contact and coil connections. Use connectors with insulated sleeves. Standard quantity: 100
BT2571 DIL3M80 to DILM820
PL-DILT TPE11DIL
TPD11DIL Sealable Shrouds Cover is fastened via a screw. Sealable to prevent access.
XGKA-U Universal Mounting Adapter
Mounting:
Self Adhesive
with M3 screw or 
cable tie Standard Quantity: 250
 
VS1DIL DIL00M-DIL2AM Contactor Mounted incoming voltage interface module with integral suppressor circuit. For energizing of the contactor from low level 24 vdc inputs. The VS1 and VS2 plug directly onto the DILM coil terminals
VS2DIL Contactor Mounted incoming voltage interface module with out  integral suppressor circuit.
ETS4-VS3 Any Contactor
with less than 2 amp coil
 
SEPARATE
 DIN RAIL MOUNT
 
For energizing of the contactor from low level 24 vdc inputs.
 
 
 
MOELLER ZE Thermal Overload Relays
is now
 EATON XTOM Thermal Overload Relays
for direct mounting to DILEM and DILEEM Contactors
SAME EXACT PART -  ONLY PART # CHANGE - CLICK THE XTCE NUMBER TO VIEW THE NEW PAGE
 
Circuit Diagram Adjustable Setting Range Normally Open Normally Closed Short Circuit Protection
by fuses max. 600 V AC by Circuit Breaker max. 600 V AC
 
ZE-0.16
ZE Overload Relay Circuit Diagram 0.1 - 0.16 1 1 1 15
ZE-0.24 0.16 - 0.24 1 1 1 15
ZE-0.40 0.24 - 0.4 1 1 1 15
ZE-0.60 0.4 - 0.6 1 1 1 15
ZE-1.0 0.6 - 1.0 1 1 3 15
ZE-1.6 1.0 - 1.6 1 1 6 15
ZE-2.4 1.6 - 2.4 1 1 6 15
ZE-4 2.4 - 4 1 1 15 15
ZE-6 4 - 6 1 1 20 15
ZE-9 6 - 9 1 1 35 15
ZE-12 9 - 12 1 1 45 15
 
 

WWW.COKGC.COM

Enquiry Mailto:

COMKGC@163.COM

→We quotation

→You Released PO

→We signed

→You  payment

→We delivery

Return to home page↑︿︿︿

 
 
 
 
 
 
 
 
 
previous posts:Fairchild
Next Article:FSG