Current:Home > A B C D
A B C D
Dosimeter Pulsar
2017-01-28 13:55:51
 
 

DSMTR;P/N:IC-DBADGE2PRO/KIT1,

DOSIMETER;
TYPE PERSONAL NOISE, RANGE 55-140 DBL, STANDARD ANSI S1.25:1991 R2007,
IEC 61252 ED 1.1 (2002-3);
Model No: model22-5 doseBadge,
Pulsar

 
 
 
 
 
 

+++++++++++++WWW.COKGC.COM  mailto:COMKGC@163.COM++++++++++++

 doseBadge Systems Personal Noise Dosimetry

The Model 22 doseBadge is compact, extremely robust and lightweight No cables or controls, reducing the risk of damage, misuse or tampering Everything you need supplied in one user-friendly system package

Ideal system for compliant assessment of workers’ Industrial Noise exposures Unique size and shape, innovative functional design

Programmable for compliance with most worldwide regulations

“Shake-to-Wake” function to extend battery life and 

operating time

Ergonomic Reader Unit with Integral Acoustic Calibrator

Infra-Red communication between Reader Unit and doseBadges Rechargeable Nickel Metal Hydride (NiMH) Battery

Outstanding Analysis & Reporting software supplied 

 

as standard

Barriers to accurately assessing the noise exposure of workers are removed with the innovative Model 22 doseBadge system. Traditional systems rely on large, cumbersome units using cables and separate microphones which can easily become damaged or tangled in machinery. 

 

The revolutionary doseBadge is a self-contained noise measurement device that has no cables, display or controls, making it an ideal solution for noise dosimetry because units can’t be tampered with during measurements.

 

doseBadges communicate with an infra-red Reader Unit - similar technology to a television remote control. The Reader Unit controls the doseBadge to program, calibrate, start/stop, download and store measurements.

 

All key measurement parameters can be viewed on the large clear backlit screen of the Reader Unit, which also displays a time history graph of workers’ daily noise exposure.

 

The Reader Unit contains an integral acoustic calibrator allowing the doseBadge to be calibrated prior to and following each measurement in accordance with international regulations. 

Worldwide Occupational or Industrial Noise Regulations require the typical daily exposure of an individual worker to be determined. The doseBadge automatically achieves this by computing the Daily Exposure for European Legislation or the Time Weighted Average for US based Legislation.

Noise dosimetry measurements are only the beginning, our effective, user friendly software package dBLink3 allows users to quickly analyse and transform data into informative report formats, simplifying a potentially complex and time consuming process. 

Full ‘time history’ information allows you to determine when key noise problems occur during a workers’ day. The additional ‘C’ weighted Peak Time History allows you to fully assess risks from impulsive noise in the workplace.

Applications

The Model 22 doseBadge systems are ideal for most applications as the preferred method of calculating personal daily noise exposures to ensure compliance with International Safety Legislation.

It is especially suitable for applications where workers are regularly moving from location to location, working with moving machinery, in difficult to reach areas, vehicle cabins, shift work or with unpredictable work patterns.

Typical industries include: Manufacturing, Construction, Chemical, Mining, Transportation, Fire and Police, Highway Maintenance, Food, Entertainment and also Educational Establishments.

Operation

Our doseBadge is rechargeable, making it more economical, and designed to run for an entire shift. The Reader Unit is used to setup and calibrate one or more doseBadges prior to use, and also to start the measurement.

The doseBadge unit logs and stores data throughout the period of measurement, and a blue indicator shows when the unit is running. At the end of the measurement, data is downloaded from the doseBadge into the Reader Unit through the infra-red link, with the Reader Unit displaying measurement data.

The Model 22 doseBadge can be configured to meet a wide range of Occupational Noise Regulations and has been designed to meet the requirements of the EU Physical Agents (Noise) Directive as well as the requirements of OSHA. In addition to the overall noise levels the doseBadge also stores a one-minute sample and one-minute Peak(C) measurement.

Configuration of the doseBadge

When used with the Model 22-R Reader Unit, the doseBadge can be configured to meet almost any current and planned occupational noise regulations and standards.

For example, in the European Union, the EU Physical Agents (Noise) Directive requires the measurement of noise exposure using a 3dB Exchange Rate and recording of LEX,8h and Peak(C), whereas the American OSHA Regulations require the use of a 5dB Exchange Rate, a Slow Time Weighting and an 80dB Threshold.

The Model 22 doseBadge can be easily configured to meet any of these requirements.

Configuration can be changed quickly and easily using the menu on the Reader Unit or by programming the Reader from the dBLink3 software.

The Model 22-R Reader Unit allows the following parameters to be configured in the doseBadge, quickly and easily:

Measurements

The user can select from a range of preset configurations which will present the commonly used noise parameters, or a ‘customised’, user-defined setup can be programmed into the doseBadge by the Reader Unit.

Overall Measurement Information

Overall Measurement Information data contains the most important and commonly used noise parameters. This data contains the Measurement Start Time and Date, Run Time, Calibration Information, Highest Peak(C) Level, 115dB(A) Maximum Sound Level Exceedence, Overload and Battery Level.

When set to the 3dB Exchange Rate, the doseBadge Overall Measurement Information contains Leq, LEX,8h (LEP,d), LAE (SEL), Exposure & Estimated Exposure in Pa2h, % Noise Dose and Estimated % Noise Dose.

When the doseBadge is configured to either 4dB or 5dB Exchange Rates, the Overall Measurement Information contains the LAVG, TWA, % Noise Dose and the Estimated % Noise Dose.

If the Time Weighting is set to Slow, or a Threshold is set, with any exchange rate (3dB, 4dB or 5dB) the Overall Measurement Information will be set to LAVG, TWA, % Noise Dose and the Estimated % Noise Dose.

Time History Data

The doseBadge measures and logs noise levels during the measurement period. In addition to the overall noise levels, such as Leq or TWA, the instrument also logs a Time History or Noise Profile.

When the doseBadge is configured to 3dB (Q=3) with no Time Weighting or Threshold, this Time History data is stored as one-minute LAeq samples. For other configurations, the Time History data is stored as LAVG.

At the same time, the doseBadge also stores the highest Peak(C) level and the Battery level every minute. This data is available with the Time History data provided by using the supplied dBLink3 software program.

Parameter Exchange rate (Q) Criterion Level Criterion Time Threshold

Time Weighing

Available Configuration 3dB, 4dB, 5dB

80dB, 85dB, 87dB,  90dB 8, 12, 16, 18 hours None, 80dB, 85dB, 90dB None or slow

Software

Our Model 22 doseBadge is supplied with the dBLink3 software program. This program uses a step-by-step wizard, which reassuringly guides the user through setup and download procedures, and allows measurement data to be viewed, analysed 

and printed.

Three pre-formatted report types are provided to present the measurement data. These reports can be printed or exported into a number of formats, including Word, Excel and PDF.

dBLink3 also supports previous versions

of the doseBadge and Reader Units,

allowing existing users to upgrade to this new program.

doseBadge Measurement Systems 

Measurement kits contain the Model 22 doseBadge units and fixing mounts, a Model 22-R Reader Unit, CHR20-XD Charger Unit (where X = 2,5 or 10), PS 22 Power Supply, K3 Hard Attache Case, USB Cable, Software, Batteries, User Manuals & Certificates of Calibration.

Optional Accessories

RK1 Keyfob remote control 

Allows the doseBadge to be started and stopped without the Model 22-R Reader Unit. This is useful in situations where there is risk of damage to the Reader Unit or additional control units are required.

WS22 Windshield for doseBadge

The WS22 Windshield protects the Model 22 doseBadge from dust, moisture and other contaminants. It also reduces the noise generated by ‘spurious’ events.

Specifications

Applicable Standards Model 22  doseBadge

IEC 61252:1993 Personal Sound Exposure Meters ANSI S1.25:1991 Personal Noise Dosemeters 

Model 22-R Reader Unit

Internal Acoustic Calibrator to IEC 60942:2001 Class 2

Ordering Codes

The Model 22 doseBadge can be provided as a complete measurement system with the following order codes:

Model 22-1 doseBadge Measurement System with 1 doseBadge Model 22-2 doseBadge Measurement System with 2 doseBadges Model 22-5 doseBadge Measurement System with 5 doseBadges Model 22-10 doseBadge Measurement System with 10 doseBadges

The measurement kits contain the Model 22 doseBadge units and fixing mounts, a Model 22-R Reader Unit, CHR20-XD Charger Unit (where X = 2,5 or 10), PS 22 Power Supply, K3 Hard Attache Case, USB Cable, Software, Batteries, User Manuals & Certificates of Calibration.

Warranty

The Model 22 doseBadge systems are supplied with a 24 month warranty.

Memory

The Model 22-R Reader Unit can store the following measurement data:

Up to 93 measurement of 8 hours duration Up to 64 measurements of 12 hours duration Up to 33 measurements of 24 hours duration

Power

Internal NiMH Battery with intelligent charging system

Model 22-R Reader

2 x AA/LR6 with Auto Power Switch Off

Chargers Units

PS22 Mains Power Supply

Output

Model 22  doseBadge 

Infrared to Model 22-R Reader Unit

Model 22-R Reader

USB 2.0 (which also provides power to the 22-R Reader)

Dimensions

Microphone Apex Ø13.0mm, Base Ø47mm, Height 38mm

Weight

Model 22  doseBadge 45gms (1.6oz) Model 22-R Reader 400gms (14oz)

Environmental

Operating Temperature -10oC to +50oC

Storage Temperature -20oC to +60oC

Humidity up to 95% RH Non-Condensing

Software

dBLink3 supplied as standard

Compatible with Microsoft Windows versions 98 or later, including Vista

Measurement Functions

doseBadge Configuration Measurement Duration Overload Exceedence

Calibration Record 

Highest Peak(C)Sound Level Battery Status

115dB(A) Maximum Sound Level Exceedence

One-Minute Time History of:

LAeq (3dB) or LAVG (4dB or 5dB) Peak(C) Level

Battery Level

For 3dB Exchange Rate

LAeq, LEX,8h, LAE, % Dose, Exposure (Pa2h), Estimated % Dose, 

Estimated Exposure (Pa2h)

For 4dB & 5dB Exchange Rates

LAVG, TWA, % Dose, Estimated % Dose

Weightings Frequency 

‘A’ for all RMS measurements. ‘C’ for Peak Sound Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+++++++++++++WWW.COKGC.COM  mailto:COMKGC@163.COM++++++++++++

Product Catalogue
We use cookies Accept Learn more
Email:comkgc@163.com
Website:www.cokgc.com
Phone:+86 13877625497
Pulsar Instruments, for noise meters, sound level meters and noise monitoring equipment
 
 
DOSIMETER
English Français Deutsch Español
HOME
ABOUT
APPLICATIONS
PRODUCTS
SERVICES
BLOG
DISTRIBUTORS
TESTIMONIALS
CONTACT
Search Results for: DOSIMETER
Take action on hearing loss
Make a Sound Investment – Take Action on Hearing Loss
This year’s World Hearing Day, organised by the World Health Organization (WHO) on 3rd March 2017, draws attention to the economic impact of hearing loss and, in particular, the…
 
Read more
Costain
Pulsar Collaborates With Costain On Noise Health Issues
Pulsar collaborates with Costain to increase awareness and staff engagement on noise health issues and come up with an innovative noise monitoring concept at The London Bridge Station Project.
To…
 
Read more
Tinnitus Awareness Week
Support Tinnitus Awareness Week 2017
Ever since we started this blog, we have covered noise-induced hearing loss and tinnitus.  As we are approaching Tinnitus Awareness Week (6-12 February 2017), we are taking the opportunity…
 
Read more
750px-Flag_of_Spain.svg
New Spanish language sound meter website launched
Expanding the sound meter business into Spanish-speaking countries
 
Pulsar Instruments Plc, the fastest growing global manufacturer of noise measurement instruments for safety professionals around the world, recently launched its new…
 
Read more
Pulsar_Instruments_Plc_MPU1252
We are exhibiting at Health & Safety Expo 2014
See industry-leading noise measurement equipment at UK's largest safety event
 
Pulsar Instruments will be exhibiting at this year’s Safety & Health Expo, Excel Centre, London, June 17-19, with their friendly…
 
Read more
noise-induced-hearing-loss-in-construction
Preventing Noise Induced Hearing Loss in Construction Workers
Overcoming the Problems Associated with Construction Noise Monitoring and Control
 
According to HSE noise statistics, the construction industry remains one of the worst offenders when it comes to occupational hearing…
 
Read more
industrialareawithcranes
How to Prevent Industrial Noise Induced Hearing Loss
Monitoring and Reducing the Risk of Noise in the Workplace
 
The risk of noise in the workplace is a very real concern for individuals and companies all over the UK….
 
Read more
Metal worker in factory grinding metal of pipeline
Pulsar Instruments Top 10 blogs of 2016
In keeping with our annual-ish tradition, we are publishing our 2016 ranking of the 10 most popular Pulsar Instruments’ blogs.
 
Here is how we have made our selection:
 
we looked at…
 
Read more
British Made Products
British-Made Noise Measurement Products Are Best
Demand for British-made products has never been so high.
 
If you are based in the UK and looking for new noise measurement equipment to carry out your noise assessments, it…
 
Read more
Helmet_250
Innovation in noise measurement: doseBadge Pulsar Model 22
The Pulsar doseBadge is a tiny, compact and lightweight dosimeter which is worn on the human body, usually on the shoulder, or on a safety helmet.  It measures accurately…
 
Read more
Noise Awareness course
Making Sense of the UK’s Noise at Work Regulations
Making Sense of Noise at Work Regulations in the workplace
 
Join the noise experts in a series of face-to-face meetings and gain vital insight on how to manage the noise…
 
Read more
Noise measurement equipment to prove noise exposure levels are within the legal limits
Before you buy a sound level meter kit
Make sure you see it before you buy a new sound level meter kit.
At Pulsar Instruments, we want you to have 100% confidence in our products.  If, after reading through…
 
Read more
Pulsar Distributors
Become A Noise Products Distributor
We thank you for visiting our website today to find out more information on the distribution opportunities in the UK and overseas for our noise measurement products here at…
 
Read more
Drapeaux_fran%C3%A7ais-200pix
Sound Meter Distributor’s Visit to Yorkshire Helps Boost Trade Links With France
French Sound Meter Distributor Gets a Warm Welcome in Yorkshire
 
The staff at Pulsar Instruments Plc welcomed Alain Gourier, Managing Director and Philippe Trautmann, Product Sales Manager, at Serac Distribution…
 
Read more
Noise_Measurement_thumbnail
Noise at Work, Workplace Noise and Issues with Noise
Noise at Work Regulations to Control Workplace Noise
 
The Control of Noise at Work Regulations (2005) became effective in 2006.  The Regulations are relevant to all employers who operate a…
 
Read more
How loud is too loud
Noise at Work – how loud is too loud
Noise at Work: How Loud is Too Loud?
Excessive noise at work can be irritating, distracting and potentially harmful to workers’ physical and mental health. The problem is, many employers…
 
Read more
Pulsar_doseBadge_Thumbnail
Controlling exposure to noise at work with personal noise dosimeters
Controlling exposure to noise at work with noise dosimeters
Our work environment has been transformed since the 1970’s with the introduction of new machinery and technical equipment designed to improve…
 
Read more
Noise: regulations, risks and controls
Noise: regulations, risks and controls
New professional course dates announced for 2017 – Noise: regulations, risks and controls.
A solid understanding of basic noise theory, regulations, risk assessment and controls and how to measure noise…
 
Read more
safeguarding hearing
Benefits of safeguarding hearing
Benefits of safeguarding hearing: how assessing noise can save your business money.
Looking through the NEBOSH National General Certificate course book recently, it surprised us to find that issues of…
 
Read more
NEWS / BLOG
 Pulsar Noise at Work  infographic.-200jpg
If you are new to noise measurement in your workplace, you will have probably started to gather as much......
 
Read more
 ear protection in industry and construction work
Part of a two-week drive to improve the working conditions at construction sites across the UK, the Health and......
 
Read more
 noisy sports main pic
What makes Formula 1 so exciting? Apart from the speed, the danger and the skill, it’s the noise of......
 
Read more
CONTACT US
Name
 
Job Title
 
Email:comkgc@163.com
 
Telephone:+86 13877625497
 
Please input characterscaptcha
 
 MAKE AN ENQUIRY
PRODUCTS
The Nova range
Pulsar NoisePen
Model 22 doseBadge
Safety professional kit
First Aid Noise at Work kit
PulsarSafeEar
The Quantifier Range
The Assessor range
Model 14
Model 105 & 106
Outdoor monitoring kit
Model 33
Noise Awareness Training Course
Technical Support
DOWNLOADS
SOFTWARE DOWNLOAD
PRODUCT BROCHURE DOWNLOAD
INFOGRAPHIC
THE SELECTION OF HEARING PROTECTION
NOISE AT WORK REGULATIONS
Find out what the employers and employees' duties are in the UK under The Control of Noise at Work Regulations (2005). Download our FREE e-guide here!
 
ACOUSTIC GLOSSARY
Learn about the most commonly-used acoustic terms to guide you when researching your next sound level meter, or other noise measurement equipment.
www.cokgc.com
SOCIAL
Copyright ©2017 Pulsar Instruments Plc. All rights reserved.
Skype:pglchintu
Pulsar Instruments are experts in the design and manufacturing of compliant noise at work measurement products to conduct occupational, general and environmental noise measurements and noise surveys.
Products include sound level meters and personal noise dosemeters, perfect for any health and safety professionals. 
 
 

Enquiry Mailto:

COMKGC@163.COM

We quotation

You side Released PO to us

We signed PO

You side payment

We delivery goods to your side.

Return to home page↑︿

 
 
 
 
previous posts:AUTOJET